The ZMUX-108E16H is a fully domestically developed SDH optical‑electrical cross‑connect device manufactured by Guangzhou YinXun, with complete independent control over the entire system. It conforms to a 19‑inch, 1U rack form factor and features eight hot‑swappable STM‑1 optical interfaces and sixteen E1 electrical interfaces. The equipment supports arbitrary timeslot cross‑connection across all ports, incorporates dual‑link and dual‑power redundancy, and is well suited for unattended sites. It is equipped with comprehensive O&M functions such as loopback detection, LED alarms, and remote network management, meeting the demands of high‑density voice networking and finding broad application in integrated transmission scenarios that require domestic‑made, secure solutions.

Keywords:

Product Overview Application Solutions Configuration Information Technical Parameters Product Documentation

  Product Overview


ZMUX-108E16H is an SDH optical-electrical cross-connect transmission device independently developed and manufactured by Guangzhou Yinxun Comm.Tech.Co..Ltd, enabling voice signal cross-connection and SDH relay transmission for the ZMUX series integrated access equipment.

The ZMUX-108E16H has achieved 100% domestic production, with independent intellectual property rights and full independent control.

The ZMUX-108E16H features a standard 19-inch, 1U rack‑mount design that is compact and aesthetically pleasing, making it suitable for installation in standard cabinets. It provides eight STM‑1 optical interfaces and sixteen E1/2M electrical interfaces, enabling any cross‑connection between STM‑1–STM‑1, STM‑1–E1, or E1–E1. Users can select either STM‑1 or E1 as the relay transmission link, and the device supports dual‑link redundancy protection.

The ZMUX-108E16H supports dual‑power‑board redundancy protection, with options for dual AC, dual DC, or a mixed AC/DC configuration, and features real-time monitoring of the device’s power supply.

 

  Features and Benefits


          Compact rack design It adopts a standard 19-inch, 1U‑height chassis with a compact design, enabling convenient installation in standard telecom cabinets and effectively saving data center space, making it ideal for high‑density deployment scenarios.
          High-reliability power redundancy : Supports dual‑power‑board redundancy protection, with optional dual AC, dual DC, or mixed AC/DC power supply modes, and features real-time power monitoring to ensure safe and stable power delivery, making it ideal for unattended sites.
          High-Capacity Interface Configuration It provides eight STM‑1 optical interfaces and sixteen E1/2M electrical interfaces, meeting the demands of high‑density voice and data access while offering ample physical port resources for integrated transport networks.
          Flexible and powerful cross‑connect scheduling, supporting arbitrary cross‑connections at the timeslot level, specifically including:
1) STM-1 optical interface ↔ STM-1 optical interface (between 8 optical interfaces) Arbitrary cross-connection of voice signals );
2) STM-1 optical interface ↔ E1 electrical interface (8 optical interfaces and 16 E1 interfaces) Electrical port between Arbitrary cross-connection of voice signals );
3) E1 electrical port ↔ E1 electrical port (16 E1 channels) Electrical port between Arbitrary cross-connection of voice signals ).

Fully meets the service routing requirements in complex network topologies.
          Multi-Relay Link Selection and Protection It allows users to freely select either an STM‑1 or E1 line as the relay transmission link and supports dual‑link redundancy with automatic switchover; when the primary link fails, it automatically switches over, thereby enhancing the reliability and survivability of network transmission.
          Convenient Operations and Maintenance and Fault Diagnosis: The STM‑1 optical ports utilize SFP hot‑swappable optical modules, supporting in‑service replacement. All optical and E1 electrical ports support software‑based loopback testing—both internal and external—enabling rapid fault localization and reducing maintenance complexity.
          Intuitive alarm indication: The device’s front panel is equipped with a comprehensive set of status indicators that provide real-time monitoring of the operating status of each optical port and E1 line, enabling operations and maintenance personnel to quickly identify anomalies in fiber-optic or E1 links and improve fault‑response efficiency.
          Intelligent Network Management and Monitoring: It provides an RS485 monitoring interface and supports both in-band and out-of-band management modes. It enables real-time online monitoring of the device’s overall operating status, the STM‑1 optical port status, and the E1 line status, facilitating centralized, unified management and remote operations and maintenance.

ZMUX-3036ESG Optoelectronic Protection Integrated Service Access Device

ZMUX-3036ESG Optoelectronic Protection Integrated Service Access Device

ZMUX-32 Multi-service Optical Terminal Unit

ZMUX-32 Multi-service Optical Terminal Unit

ZMUX-30 PCM Multiplexing Equipment Network Diagram

ZMUX-30 PCM Multiplexing Equipment Network Diagram

ZMUX-3036 Intelligent PCM Multiplexing Equipment

ZMUX-3036 Intelligent PCM Multiplexing Equipment

ZMUX-3030 PCM Multiplexing Equipment

ZMUX-3030 PCM Multiplexing Equipment

Air Traffic Control and Airport Communication Solutions

Air Traffic Control and Airport Communication Solutions

 

Configuration Hierarchy

Configuration Item

Specification Model

Specifications and Parameters

Quantity

Optional Configuration Status

Basic System

Equipment chassis and main system board

ZMUX-108E16H

1U-height chassis, rack-mountable;

8-channel STM-1 optical interface;

16 E1 link interfaces;

A 2-way 220 VAC / -48 VDC power interface is optional.

1 unit

Must-have

  Custom-made on demand


Specifications and dimensions
        266 mm (depth) × 483 mm (width) × 44 mm (height)


Work environment

Temperature: 0–70°C

Humidity: ≤90% (non-condensing)

Atmospheric pressure: 70–106 kPa


Equipment power supply

DC power input voltage: -48 VDC

DC power input voltage range: -36 VDC to -72 VDC

AC power input voltage: 220 VAC

AC input voltage range: 110 VAC ~ 253 VAC

Device power consumption: ≤50W

Protection: Supports dual-power 1+1 redundancy protection


Network Management Monitoring Interface

Serial Port Monitoring Mode

Interface Type: RS485

Interface rate: 9.6 kbps


Fiber optic interface

Number of interfaces: 8 channels

Transmission rate: 155 Mbit/s ± 4.6 ppm

Interface standard: ITU-T G.707 / G.957, STM-1 (SDH)

Code Type: NRZ Scrambling

Wavelength: 1310 nm / 1550 nm

Optical transmit power: ≥ -5 dB

Receiving sensitivity: ≥ -36 dB

Transmission distance: 40 km / 60 km / 80 km / 100 km optional

Connector: LC (Duplex/Single-mode/LC)


E1 interface

Number of interfaces: 1–16 channels

Bit Rate: 2048 Kbps ± 50 ppm

Code Type: HDB3

Interface impedance: 75 Ω unbalanced or 120 Ω balanced

Standard: Complies with ITU-T G.703 and G.704 technical standards.

Compatibility: Compatible with mainstream cryptographic devices

Name

Last updated

Size

Enter information to obtain information

By systematically retrieving and analyzing the relevant input information, detailed and professional information can be obtained to support or meet specific needs or goals.

Confirm
%{tishi_zhanwei}%

Recommended Products

Product Message

Fill in the message form and leave your contact information. Our staff will contact you within 24 hours (workdays).

Leave A Message


Fill in the message form and leave your contact information. Our staff will contact you within 24 hours (workdays).